 Model Number ETOS-DNA PLUS Sereis

Features

  • Offers Ethernet 1 port(100baseT/DHCP/Communication Drivers)
  • Up to 4 serial communication ports(RS232/ RS422)
  • Supports wire(Dedicated Modem) and wireless(CDMA/RF Modem)
  • Function to be sending SMS with CDMA Modem(Event Alarm function)
  • Various I/O formations(Relay and TR output/ Analog and DC input)
  • Possible to use as redundant RTU that is consisted of wire and wireless way
  • Controller for controlling and monitoring of unmanned remote sites

Modules

Classification Model Specification
Main
(Classify by port)
ETOS-DNA-PLUS-S20 Serial(RS232) 2 ports
ETOS-DNA-PLUS-S02 Serial(RS422) 2 ports
ETOS-DNA-PLUS-S40 Serial(RS232) 4 ports
ETOS-DNA-PLUS-S04 Serial(RS422) 4 ports
ETOS-DNA-PLUS-S22 Mixed Serial RS232 2 Ports, RS422 2 Ports
ETOS-DNA-PLUS-E20 Ethernet 1 Port + RS232 2 Ports
ETOS-DNA-PLUS-E02 Ethernet 1 Port + RS422 2 Ports
ETOS-DNA-PLUS-E40 Ethernet 1 Port + RS233 4 Ports
ETOS-DNA-PLUS-E04 Ethernet 1 Port + RS422 4 Ports
ETOS-DNA-PLUS-E22 Ethernet 1 Port + RS232 2 Ports / RS422 2 Ports
Option
(Classify by I/O)
DNA-PLUS-OPT-RY16 Relay Output 16 Points
DNA-PLUS-OPT-TR16 TR Output 16 Points
DNA-PLUS-OPT-DC16 DC24V Input 16 Points
DNA-PLUS-OPT-DT15 TR output 7 Points / DC 24V Input 8 Points
(for combined input and output)
DNA-PLUS-OPT-DR16 Relay Output 8 Points / DC24V Input 8 Points
(for combined input and output)
DNA-PLUS-OPT-AD4 Analog Input 4 ch

The methods to classify Main Model name : ETOS-DNA-PLUS-X,Y,Z-AA

  • X : Classify Ethernet and Serial : S = Serial, E = Ethernet
  • Y : Quantity of RS 232 Ports
  • Z : Quantity of RS 422 Ports
  • AA : User Memory Size (none, 1M, 2M, 4M)
  • ex : ETOS-DNA-E22 = Ethernet 1Port, RS232 2 Ports, RS422 2 Ports, 256kbyte user Memory

Digital Output Specification

Classification DNA-PLUS-OPT-RY16 DNA-PLUS-OPT-TR16
Input/ Output Spec. Relay Output TR Output
Input/ Output Points 16 Points 16 Points
Isolation method Relay Isolation Photo coupler Isolation
Polarity Type - Sink type(-COM)
Rated Load Voltage DC24V, AC110V/220V DC12V, DC24V
Rated Load Current 5A/COM 3A/COM
Response time Off->On 10 mSecs 2 mSecs
On->Off 12 mSecs 2 mSecs
Common method 8 Points / 1 COM 16 Points / 1 COM
Status Display Display by LED Display by LED

Digital Input/Output Specification

Classification DNA-PLUS-OPT-DC16 DNA-PLUS-OPT-DT15 DNA-PLUS-OPT-DR16
Input/ Output Spec. DC Input module Mixed DC Input/ TR Output Mixed DC Input/ Relay Output
Input/ Output Points Input 16 Points Input 8 Points
/ Output 7 Points
Input 8 Points
/ Output 8 Points
Isolation method Photo coupler Isolation Photo coupler Isolation Photo coupler Isolation
Polarity Type Source/Sink
(non-Polarity)
- -
Rated Load Voltage/ Current Input DC24V/11mA Refer DC input Module Refer DC input Module
On Voltage/Current Input DC15V/6mA - -
Off Voltage/Current Input under DC5V/1mA Refer TR Output Module Refer Relay Output Module
Response time Off
->On
10mSecs - -
On
->Off
10mSecs
Common method 8 Points / 1 COM Input 8 Points/1COM
Output 7Points/1COM
Input 8 Points/1COM
Output 8Points/1COM
Status Display Display by LED Display by LED Display by LED

Analog Input Specification

Classification DNA-PLUS-OPT-AD4
Input Spec. Analog Input Voltage/Current Module
Number of Input Channels 4 Channels
Input Voltage DC -10V~+10V, -5V~+5V, 0~10V, 0~5V, 1~5V
Current DC 1~20mA, 4~20mA
Selecting Voltage/Current Selecting by Terminal
Digital Output -16000 ~ +16000
Resolution Voltage 0.25 mV
Current 1 uA
Precision Rate ± 0.1%(Full Scale)
Isolation method Isolating Input Terminal and Internal circuits by Photo Coupler(Non-Isolation between channels)
Max. Converting Speed 10mSec / 1 Channel
Internal Process Average Process(Average Value Setting function), Sampling
Status Display Display by LED

ETOS-DNA Analog / Digital Input / Output Wiring Diagram

16 Points Relay Output Terminal Wiring 16 Points TR Output Terminal Wiring
16 Points DC Input Terminal Wiring DC 8 Points/Relay 8 Points Mixed Type Terminal Wiring
DC 8 Points/TR 7 Points Mixed Type Terminal Wiring 4 Channel Analog Input Terminal Wiring

Monitoring Systems about an amount of flowing in unmanned Distributing